Detailed description
The indicator has standard EN 175301-803 (former DIN 43650) male and female connectors, placed at the top and botom respectively.
ENVIRONMENTAL CONDITIONS :
Operating temperature : -40 to 85 °C
Power supply : current loop 4 to 20 mA
MAXIMUM CURRENT LOOP : 60 mA
INDICATION RANGE : -1999 to 9999 / 9999 to -1999
DISPLAY RESOLUTION : 11998 level ( -1999 to 9999)
ACCURACY OF THE INDICATED VALUE : 0,1 % of range ± 1 digit (@ 25°C)
SAMPLING RATE : 100 ms
THERMAL COEFFICIENT : 0,005 % / °C of range
VOLTAGE DROP IN THE INDICATOR :
< 10 mA : < 5,4 V
10 to 12 mA : < 3,9 V
> 12 mA : < 2,8 V
BOX : ABS (polyurethane gasket)
PROTECTION : IP65, NEMA4X
CERTIFICATION : CE