INPUT
- Pressure Range in BAR : 1 / 2 / 3.5 / 5 / 10 / 20 / 35 / 50 / 100
- Pressure Range in PSI : 15 / 30 / 50 / 75 / 150 / 300 / 500 / 750 / 1500
- Pressure Type : Absolute
- Over Pressure : 3 Times Rated Pressure or 850 bar whichever is less
- Burst Pressure : > 200 bars (2900 PSI); > 850 bar (12325 PSI)
- Pressure Media : Any Liquid or Gas Compatible With 15-5 PH or Stainless Steel
- Electrical Input : < 10 mA
- Supply voltage 12 – 36 VDC or 1.8 – 6 VDC
OUTPUT
- Full Scale Output (FS) : 4 Vdc ± 50 mV (0.5 V to 4.5 V output signal)
- Output Impedance : 1 kΩ
- Zero offset at 20 °C : 0.5 V ± 50 mV
- Bandwidth (-3dB) : 4.5 kHz
- Combined Non-Linearity & Hysteresis : ± 0.25% FS (Max)
- Repeatability : ± 0.2% FS
- Insulation : 100 MΩ @ 50 Vdc
ENVIRONMENTAL
- Operating Temperatures : -40°C to +85°C
- Compensated Temperatures : 0 °C to 60 °C (see Options for other range)
- Thermal Zero Shift : < ± 3% FS / 50 °C
- Thermal Sensitivity Shift : < ± 2% FS / 50 °C